Amsterdam, Netherlands
Equinix AM4 datacenter
Actiflow’s extensive study helped to complete the risk-assessment, to optimize the design and to determine the energy use of the data centre.
Actiflow provided the necessary insight
Pompenburg is a new construction project that will be completed between 2024 and 2026 northeast of the center of Rotterdam. The planning area creates a corridor between the center and North Rotterdam and is characterized by predominantly high-rise buildings, including four residential buildings with towers.
Case details
About the client
Equinix is the leading global interconnection and datacentre company. Equinix data centres are located throughout most of the world, across five continents. Amsterdam is a network-rich and cloud dense location and is one of the most important central connectivity hubs in the world. Equinix currently operates 8 locations in Amsterdam and 2 in the east of the Netherlands.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Fusce posuere ex sed dui posuere imperdiet. Sed viverra finibus nisl, eu euismod ipsum molestie tempus. Vestibulum non rhoncus mauris. Nunc eget lacus tortor. Vivamus hendrerit urna et ante bibendum, ac faucibus ipsum pellentesque. In tincidunt metus in ex porttitor, at dignissim elit varius. Nullam feugiat nunc ac quam pellentesque.
The challenge
In 2017 Equinix opened the AM4 data centre at the Amsterdam Science Park campus. This unique data centre consists out of a lower part (the existing AM3 data centre) and a high-rise part (the AM4 data centre). This combination provided several engineering challenges during the design and construction phase. One of these was the discharge of hot air and fumes from the cooling devices and emergency power units. The relatively small space available makes it less self-evident that the flow of fresh air towards and discharged air and fumes from the data centre are always separated.
The Solution
Equinix’s subcontractors Unica and RHDHV asked Actiflow to perform an extensive analysis of the flow around the building. Therefore we made a detailed computational model including the surrounding buildings, all cooling devices on the roofs of AM3 and AM4, all exhausts and intakes and details like porous screens, lamellas and falls roofs. We then used this model to calculate the flow of air and the distribution of temperature and water vapour in several scenarios. These scenarios vary in operational mode (normal, maintenance, emergency) and weather conditions (high or low temperature, wind speed and direction).
Results
The study provided both the subcontractors and Equinix with extensive insights in what could happen under a variety of circumstances. It was used to complete the risk-assessment, to optimize the design and to determine the energy use of the data centre. The insight the CFD-study provided made it possible that the related engineering challenges were solved to an optimum.
“Communication with our partners at Actiflow is smooth and pleasant. They always keep their promises and their studies result in reliable and ready-to-use information. In short, we are very satisfied!”
Erwin van den Hove
Director of Project and Plan Development
Conclusion
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Maecenas nec sodales sem, in varius dui. In libero lacus, luctus at tellus at, molestie fringilla tellus. Vivamus quis fermentum leo. Nam nec diam convallis erat tincidunt bibendum. Nam a euismod libero, sagittis tempus augue. Vestibulum luctus libero sed leo accumsan pellentesque.