Wind Engineering

Windmill biotopes

We study the impact of a new building on the operation of historical windmills

Whitepaper

Designing with wind: how do you solve wind problems?

Home > Services > Wind Engineering > Windmill biotopes

Enabling urban development while preserving historical heritage

The Netherlands is world-famous for its historic windmills. Originally constructed in open landscapes, many of these mills are now located near expanding urban areas. As cities grow and new buildings are constructed, the local wind climate is influenced and as such the ability of windmills to capture wind.

When new developments are planned within the vicinity of a historic windmill, it is essential to assess the impact on mill’s operational performance. A windmill biotope study evaluates how a proposed building affects wind availability and the number of operational hours of a mill.

Our Clients

At Actiflow, we help to enable sustainable urban development while safeguarding valuable cultural heritage. This typically requires an integral approach involving all stakeholders: real estate developers, urban planners, millers, windmill foundations, municipalities and planning authorities. By cooperating, we ensure that historic windmills remain functional for generations to come.

When new (high-rise) buildings are planned within several hundreds of metres of a historic windmill, we assist developers to study the impact of the proposed project on the windmill’s wind capture and operation. For new masterplans or urban developments, the responsibility for conducting a wind study often lies with the planning authorities.

In other cases, we support millers if they believe a proposed development could negatively affect the mill’s performance.

Our services

Depending on the project scope and the specific research questions, we offer two types of windmill biotope assessments:

Windmill biotope quick scan

A biotope quick scan provides a fast, cost-effective initial assessment.

The study begins with a simplified windmill biotope equation to determine the maximum allowable building height as a function of the distance from the windmill. If the proposed building exceeds this limit, we estimate the expected reduction in the windmill’s operational hours based on the direction and distance of the proposed building relative to the windmill, as well as local statistical wind data.

The quick scan assumes no wind recovery downstream of the proposed building. As a result, it represents a conservative, worst-case assessment.

Detailed windmill biotope study

For more complex projects, we conduct a detailed windmill biotope study using Computational Fluid Dynamics (CFD) simulations.

This study includes:

    • All steps of the quick scan
    • A high-resolution 3D model of the windmill’s surroundings (typically within a 400-metre radius)
    • Wind simulations for twelve wind directions
    • Comparative simulations with and without the proposed development

This “before and after” approach enables an accurate assessment of the actual impact of the proposed development on the windmill’s operational hours.

How we work

Currently, there is no universally accepted standard methodology for conducting windmill biotope studies in scientific literature or regulations.

At Actiflow, we apply a methodology based on steady-state CFD simulations, which we consider the most practical and reliable approach available today.

Why CFD?

Compared to simplified distance-height equations, CFD simulations provide:

    • Detailed insight into actual wind behaviour
    • Spatial variation of wind speed across the rotor area
    • Accurate modelling of building-induced wind disturbances
    • Quantification of operational hour losses

By combining CFD results with long-term statistical wind data, we calculate the reduction in operational hours in a scientifically robust yet practical manner.

Limitations and Transparency

Like any modelling technique, steady-state CFD simulations have their limitations:

    • Potential overestimation of building wakes
    • No explicit resolution of transient turbulence
    • Gusting or dynamic wind effects are not taken into account

We acknowledge these limitations and ensure that results are interpreted accordingly. Despite these limitations, steady-state CFD offers an optimal balance between physical accuracy, computational feasibility, and project budget.

For developers, municipalities, and millers, our CFD-based windmill biotope studies provide relevant, realistic and transparent insights.

Relevant Projects

Why Choose Actiflow?

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.